What Transport Canada published
- Recall number
- 2004154
- Recall date
- 6 May 2004
- Make
- Mercedes-Benz
- Models
- S Class, Cl Class
- Model years
- 2000 to 2001
- Vehicle class
- Car
- System
- Electrical
- Raised as
- Safety Mfr
- Vehicles affected
- 2,246
- Register
- Canada — Transport Canada, Vehicle Recalls Database
On certain vehicles, the size of the electric conductor on the blower motor fuse holder may be below appropriate tolerances. Consequently, the electric conductor of the blower motor fuse holder may dissipate more heat than the plastic fuse holder was designed to withstand, which would result in partial melting of the blower motor fuse holder and disabling of the blower motor. Correction: Dealers will replace the blower motor fuse holder.
The wording above is the department's own, as it stood in the monthly file this site last read. Vehicle counts are the sum of the counts published for each make and model the recall covers. To act on a recall, use the official notice: Transport Canada recall 2004154.